INSTALLER'S RESPONSIBILITY
Installer Please Note: This equipment has been tested and inspected. It has been shipped
free from defects from our factory. However, during shipment and installation, problems such as
loose wires, leaks or loose fasteners may occur. It is the installer's responsibility to inspect
and correct any problems that may be found.
The model and serial numbers are located on the data plate attached to the side of the cooler.
Record this information in the spaces provided below.
Model No. Serial No.
Maintain water in sumps by proper microbicidal water treatment to mini-
mize the risks of illness caused by Legionella Pneumophila (the bacteria that causes
Legionnaire's Disease) and other bacteria. Refer to local codes regarding any additional
treatment or restrictions regarding water supplies and usage.
INSTALLATION SERVICE MANUAL
OUTDOOR ROOFTOP EVAPORATIVE COOLING UNITS
*Unit Type (EV) - Capacity (CA) - (10-40)
Evaporative Cooling systems meet a wide range of heating and ventilating requirements. The Evaporative Cooler
may be purchased as an individual unit in four sizes from 800 CFM to 8500 CFM (0.4 to 4.0 m
3
/s) or, it can be
combined with Rooftop Packaged Units (Natural or Power Vented), Air Handlers, or Make-up Air Handlers. In any
combination, the Evaporative Cooler will replace the need for 100% Outside Air Inlet Hood.
Evaporative Cooling is the simplest and most-cost effective cooling method without the use of mechanical
refrigeration.
*This manual may also be used for the following:
Unit Types (UT) - (RT or PV)
Rooftop Arrangements (RA) - (D or E) and
Unit Type (UT) - (AH)
Rooftop Arrangements (RA) - (P or R)
Capacity (CA) - (20 or 40)
ATTENTION: Read This manual IIEVC, manuals RISM* and RBM*, submittal/data sheets,
and all labels attached to the unit carefully before attempting to install, operate, or ser-
vice the Evaporative Cooling Unit! Retain this manual for future reference.
FPO
260 NORTH ELM ST., WESTFIELD, MA 01085
TEL: (413) 568-9571 FAX: (413) 562-8437
www.mestek.com
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - INSTALLATION SERVICE MANUAL

IIEVC-6J30-05401INSTALLER'S RESPONSIBILITYInstaller Please Note: This equipment has been tested and inspected. It has been shipped free from def

Seite 2 - GENERAL SAFETY INFORMATION

– 10 –ELECTRICAL CONNECTIONS Do not use any tools (i.e. screwdriver, pliers, etc.) across the terminals to check for power. Use a voltmeter. USE CO

Seite 3 - Air Pressure Drop Inches - WG

– 11 –ELECTRICAL CONNECTIONS (continued)Figure 9Figure 10

Seite 4 - Table 2A

– 12 – Open all disconnect switches and secure in that position before servicing unit. Failure to do so may result in personal in

Seite 5 - Table 2B

– 13 –Washing the Media Avoid splashing water on the blower motor at all times (this could cause electrical problems)!1. Scale and dust s

Seite 6 - CAPACITY A B C G ▲J

– 14 –Roof Curb Kit - RC015* (-1, -2, -3, -4)For use with:Unit type (UT) - EVCapacities (CA) - 10/40*Evaporative Cooler Platform Only(Included with Ro

Seite 7 - PARTS IDENTIFICATION

– 15 –How to order Replacement Parts Please provide the following information to your local representative: • Model Number • Serial Number (if any)

Seite 8 - ADJUSTMENT SCREW

260 NORTH ELM ST., WESTFIELD, MA 01085TEL: (413) 568-9571 FAX: (413) 562-8437www.mestek.com

Seite 9

– 2 –RECEIVING INSTRUCTIONSInspect shipment immediately after receiving to determine if any damage has occurred during shipment If any damage is foun

Seite 10 - ELECTRICAL CONNECTIONS

– 3 –4"(102)8" CELdek®(Optional 12")2" CELdek®OverflowPumpBallValve1/4" WaterInletFloat ValveBleed-offWaterDistributionAssemb

Seite 11 - Figure 10

– 4 –Rooftop Packaged Unit with Evaporative CoolingFigure 3 - Natural Vent Rooftop Unit with Evaporative Cooler (without Supply Plenum) A.G.A. C.G.A.

Seite 12 - MAINTENANCE

– 5 –Rooftop Packaged Unit with Evaporative CoolingFigure 4 - Natural Vent Rooftop Unit with Evaporative Cooler (with Supply Plenum) A.G.A. C.G.A. G

Seite 13 - AIR FLOW

– 6 – CAPACITY A B C G ▲J 20 43-7/8" 23-13/16" 21-15/16 42-1/16" 35" (1114) (605) (557) (1068) (889) 40 60-3/8&qu

Seite 14

– 7 –EVAPORATIVE COOLER PARTS IDENTIFICATION161514324567891011112 9. Pump Support Bracket10. Pump11. Poly Tubing - 1/4" O.D.12. Pump Basket S

Seite 15 - LIMITED WARRANTY

– 8 –Figure 7 - Float Valve AssemblyNOTICE: There will be a slight odor during the initial start-up of the unit. The odor will disappear within the fi

Seite 16

– 9 –Bleed-OffBleed-Off is required to maintain the water quality of the system. When water evaporates, minerals and other impurities are left behind,

Kommentare zu diesen Handbüchern

Keine Kommentare