3. Install the Electrical Outlet
CAUTION: Risk of personal injury. Do not turn on the power until instructed to do so.
NOTE: The whirlpool is equipped with a cord and plug. All pump and control wiring has been completed
at the factory.
NOTE: Refer to the label near the pump. This label identifies the electrical rating and model number of the
whirlpool.
Install a GFCI-protected, 120 V, 15 A grounded outlet behind the whirlpool and within 24 (610 mm)
of the pump location. No other load should be on this circuit.
Install a bonding (grounding) conductor at the future location of the pump in accordance with any
applicable local codes.
Bond in accordance
with applicable codes.
Install a GFCI-protected 120 V,
15 A grounded outlet.
Sterling 7 1016902-2-F